Product Highlights

  • Single-port, simultaneous dual-wavelength feature completes testing in half the time and saves measurements from both wavelengths into one record
  • CheckActive feature emits an audible tone and displays an icon when a live fiber is detected, eliminating the need to set up a measurement
  • FindFiber Remote ID enables one individual to quickly identify cable connections or routings (especially useful at patch panels), eliminating the need for multiple technicians on opposite ends of a fiber link to match color combinations
  • Min/Max capability automates precision tracking of intermittent power fluctuations
  • Large internal memory save 1000 results which enables continuous testing and recording
  • LinkWare Cable Test Management software helps to analyze test results and create professional test reports

Each Unit Includes

  • SimpliFiber Pro Optical power meter
  • 850/1300 multimode source
  • VisiFault VFL
  • FindFiber Remote ID sources
  • Magnetic Strap attachments
  • Carrying case
  • ST and LC adapter
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Environmental Specifications
Operating Temperature -10º C to 50º C
Storage Temperature -20º C to 50º C
Operating Humidity
  • 95% (10º C to 35º C) Non-Condensing
  • 75% (35º C to 40º C) Non-Condensing
  • Uncontrolled <10º C
EMI, RFI, EMC Standards compliant1

1 Conforms to relevant European Union directives; Conforms to relevant Australian standards; Listed by the Canadian Standards Association; Complies with 21CFR.1040.10,11, and EN60825-1, 2:2007 (Class 1, Hazard Level 1)
 

Optical Power Meter
Detector Type InGaAs
Calibrated Wavelengths 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm
Measurement Range
  • +10 to -52 dBm (850 nm)
  • +10 to -60 dBm (1300, 1310, 1490, 1550, 1625 nm)
Power Measurement Linearity
  • ±0.2 dB (850 nm)1
  • ±0.1 dB (1300, 1310, 1490, 1550, 1625 nm)2
Power Measurement Uncertainty3 ±0.25 dB
Display Resolution, dB or dBm 0.01 dB
Auto Dual-Wavelength Switching Yes
Power Display Units dBm, mW, μW
Auto-Wavelength Detection Yes
Data Storage 1000 records, multiple wavelengths per record
External Interface USB, 2.0 full speed
Optical Connector Removable adapter, SC adapter as default, optional adapters include LC, ST
Display update rate 1 reading per second
Reference Individually set for each wavelength
FindFiber ID detection Yes
Power Requirement 2 AA Alkaline batteries
Battery Life4 > 50 Hours (typical)
Automatic Power Off 10, 20, 30 or 60 minutes (can be disabled by user)
Low Battery Warning Yes, low battery icon blinks
Size (L x W x H) 6.4 in x 3.2 in x 1.5 in (16.5 cm x 8.0.cm x 3.9 cm)
Weight 11.5 oz (325 grams)

1 For 850nm, ±0.2 dB for power from 0 to -45 dBm, ±0.25 dB for power < -45 dBm
2 ±0.1dB for power from 0 to -55 dBm, ±0.2 dB for power > 0 dBm and < -55 dBm
3 23°C ±2°C, power level -20dBm, continuous wave, 62.5/125µm at multi mode wavelengths, 9/125 µm at 1310,1490, 1550 and 1625 nm; add 0.1 dB for 1625 nm,
4 For measured power levels 0 dBm or less, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
 

Multimode Optical Source
Emitter Type LED
Central Wavelength 850 nm, 1300 nm
Wavelength Accuracy
  • 850 nm: +/-30 nm
  • 1300 nm: +/- 20 nm
Spectral Width (FWHM)
  • 850 nm: 50 nm (typical)
  • 1300 nm: 135 nm (typical)
Minimum Output Power 850/1300 nm: ³  -20 dBm
Power Output Stability1 ±0.1 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled/disabled by user.
Optical Output Connector Fixed SC
FindFiber Code Generation Yes. Fixed at ID 1.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries.
Battery Life2 40 hrs (typical)
Automatic Power Off 30 minutes (can be disabled by user)
Low Battery Warning Yes, LED blinks
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 1.8 oz (278 g)

1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
 

Singlemode Optical Source
Emitter Type 1310 nm/1550 nm: dual FP laser
1490 nm/1625 nm: dual DFB laser
Central wavelength
  • 1310 nm: ±20 nm
  • 1550 nm: ±30 nm
  • 1490 nm: ±3 nm
  • 1625 nm: ±5 nm
Wavelength Accuracy
  • 1310 nm: +/- 20 nm
  • 1550 nm: +/- 30 nm
Spectral width (RMS)
  • 1310 nm: 2 nm (maximum)
  • 1550 nm: 3 nm (maximum)
  • 1490 nm/1625 nm: 1 nm (maximum)
Minimum output power 1310/1550 nm ≥ -7dBm (typical)
1490 nm/1625 nm: ≥ -3 dBm (typical)
Power Output Stability1 ±0.25 dB over 8 hours
Auto Dual-Wavelength Switching Yes. Can be enabled or disabled by user.
Optical Connector Fixed SC
Launch Condition 9/125 μm fiber
FindFiber Code Generation 1310/1550 source is fixed at ID 2
1490 nm/1625 nm is fixed at ID 3.
Modes CW, 2 kHz modulated, Auto-wavelength
Power Requirement 2 AA Alkaline batteries
Battery Life2 30 hrs (typical)
Automatic Power Off 30 minutes (can be enabled or disabled by user)
Low Battery Warning LED blinks.
Size (L x W x H) 5.6 in x 3.2 in x 1.6 in (14.2 cm x 8.1 cm x 4.1cm)
Weight 9.8 oz (278 grams)

1 23° C ± 2° C, after 5 minutes warm-up time
2 In auto-wavelength mode, battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
 

FindFiber Source Specifications
Emitter Type Laser
Source Connector Fixed SC
FindFiber Code Generation 1 through 8. Default is 3.
Power On/Low-battery Indicator LED
Power Requirement 2 AA Alkaline batteries
Battery Life > 80 Hours (typical)
Automatic Power Off 30 minutes
Low Battery Warning LED blinks
Size (L x W x H) 7.1 in x 1.3 in x 1.0 in (17.9 cm x 3.2 cm x 2.5 cm)
Weight 4.4 oz (125 g)
Safety Meets Class 1 CDRH