Fluke 754 for Rent, Multifunction Documenting Calibrator

Multifunction Documenting Calibrator

Order #: 754-RENT1

Mfg #: 754-RENT1

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price
Availability:
In stock
This item is available USED at
$9,798.60
Shop now
This item has NEW version starting at
Special Price $12,605.09 Regular Price $14,163.03
Shop now

Overview

You're going to love what we've done with your calibrator.

The 754 is everything you needed and wished for in the 744 and more! HART communication capability is combined to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.

The 754 does the work of several tools - sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You'll fall in love with the new improved graphical screen, Li-Ion battery for longer life, USB port and new accessories to complete the package.

For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.

HART Capabilities

The 754 is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers most of the communication capabilities of a HART communicator.

Product Highlights

  • Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
  • Source/simulate volts, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
  • Power transmitters during test using loop supply with simultaneous mA measurement
  • Measure/source pressure using any of 29 Fluke pressure modules
  • Advanced features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
  • Includes HART communication for adjusting and testing HART smart transmitters.
  • Includes the new C799 Field soft case
  • Three-year warranty

Each Unit Includes

  • Three sets of stackable test leads
  • Three sets of TP220 test probes with three sets of “extended tooth” alligator clips
  • Two sets AC280 hook clips
  • BP7240 Li-ion battery pack
  • BC7240 battery charger
  • C799 field soft case
  • USB communication cable
  • Getting started guide
  • Instruction manual on CDROM
  • NIST traceable certificate of calibration
  • DPCTrack™ 2 sample software
  • HART communication cable
Transcat Rentals - Rent Equipment from the Industry Leader
   Try Before You Buy
   Save Time & Money
   Weekly and Monthly Rentals
   Access Our Large Inventory
   Long-term Discounts and Rent-to-Buy Options Available

Shop all Rentals

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
  1. Rent Fluke 80PK-27 Surface Probe
    Fluke 80PK-27 for Rent, SureGrip Industrial Surface Type K, Thermopcouple Probe
    SureGrip Industrial Surface Type K T/C Probe

    Order #: 80PK-27-RENT1

    Mfg #: 80PK-27-RENT1

    Availability: Call for Availability
    Call for price
Measurement Accuracy
 Range/Resolution1 Year2 Years 
Voltage DC 100.000 mV 0.02% + 0.005 mV 0.03% + 0.005 mV  
3.00000 V 0.02% + 0.00005 V 0.03% + 0.00005 V  
30.0000 V 0.02% + 0.0005 V 0.03% + 0.0005 V  
300.00 V 0.05% + 0.05 V 0.07% + 0.05 V  
Voltage AC 3.000 V (40 Hz to 500 Hz) / 0.001 V 0.5% + 0.002 V 1.0% + 0.004 V  
30.00 V (40 Hz to 500 Hz) / 0.01 V 0.5% + 0.02 V 1.0% + 0.04 V  
300.0 V (40 Hz to 500 Hz) / 0.1 V 0.5% + 0.2 V 1.0% + 0.2 V  
Current DC 30.000 mA 0.01% + 5 uA 0.015% + 7 uA  
110.00 mA 0.01% + 20 uA 0.015% + 30 uA  
Resistance 10.000 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ  
100.00 Ω 0.05% + 50 mΩ 0.07% + 70 mΩ  
1.0000 kΩ 0.05% + 500 mΩ 0.07% + 0.5 Ω  
10.000 kΩ 0.1% + 10 Ω 0.15% + 15 Ω  
Frequency 1.00 to 110.00 Hz / 0.01 Hz   0.05 Hz  
110.1 to 1100.0 Hz / 0.1 Hz   0.5 Hz
1.101 to 11.000 kHz / 0.001 kHz   0.005 kHz  
11.01 to 50.00 kHz / 0.01 kHz   0.05 kHz  
Source Accuracy
 1 Year2 Years 
Voltage DC 100.000 mV 0.01% + 0.005 mV 0.015% + 0.005 mV  
1.00000 V 0.01% + 0.00005 V 0.015% + 0.0005 V  
15.0000 V 0.01% + 0.0005 V 0.015% + 0.0005 V  
Current DC 22.000 mA (source) 0.01% + 0.003 mA 0.02% + 0.003 mA  
Current sink (simulate) 0.02% + 0.007 mA 0.04% + 0.007 mA  
Resistance 10.000 Ω 0.01% + 10 mΩ 0.015% + 15 mΩ
100.00 Ω 0.01% + 20 mΩ 0.015% + 30 mΩ  
1.0000 kΩ 0.02% + 0.2 Ω 0.03% + 0.3 Ω  
10.000 kΩ 0.02% + 3 Ω 0.03% + 5 Ω  
Frequency 0.1 to 10.99 Hz   0.01 Hz  
0.01 to 10.99 Hz   0.01 Hz  
11.00 to 109.99 Hz   0.1 Hz  
110.0 to 1099.9 Hz   0.1 Hz
1.100 to 21.999 kHz   0.002 kHz  
22.000 to 50.000 kHz   0.005 kHz  
Technical Data
      
Data log functions Measure functions Voltage, current, resistance, frequency, temperature, pressure
Reading rate 1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length 8000 readings (7980 for 30 or 60 readings/minute)
Ramp functions Source functions Voltage, current, resistance, frequency, temperature
Rate 4 steps/second
Trip detect Continuity or voltage (continuity detection not available when sourcing current)
Loop power function Voltage Selectable, 26 V
Accuracy 10%, 18 V minimum at 22 mA
Maximum current 25 mA, short circuit protected
Maximum input voltage 50 V DC
Step functions Source functions Voltage, current, resistance, frequency, temperature
Manual step Selectable step, change with arrow buttons
Autostep Fully programmable for function, start delay, stepvalue, time per step, repeat
Environmental Specifications
      
Operating temperature -10°C to +50°C
Storage temperature -20°C to +60°C
Dust/water resistance Meets IP52, IEC 529
Operating altitude 3000 m above mean sea level (9842 ft)
Safety Specifications
      
Agency approvals CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Mechanical and General Specifications
      
Size 136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
Weight 1.2 kg (2.7 lb)
Batteries Internal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh
Battery life >8 hours typical
Battery replacement Replace without opening calibrator; no tools required
Side port connections Pressure module connector
USB Connector to interface to your PC
Digital instrument (HART) connector
Connection for optional battery charger/eliminator
Data storage capacity 1 week of calibration procedures results
90 day specifications The standard specification interval for the 750 Seriesare 1 and 2 years.
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
Temperature, Resistance Temperature Detectors
      
Degrees or % of reading - Type (α) Range °C Measure °C1
  1 year 2 year
100 Ω Pt (385) -200 to 100 0.07°C 0.14°C
100 to 800 0.02% + 0.05°C 0.04% + 0.10°C
200 Ω Pt (385) -200 to 100 0.07°C 0.14°C
100 to 630 0.02% + 0.05°C 0.04% + 0.10°C
500 Ω Pt (385) -200 to 100 0.07°C 0.14°C
100 to 630 0.02% + 0.05°C 0.04% + 0.10°C
1000 Ω Pt (385) -200 to 100 0.07°C 0.14°C
100 to 630 0.02% + 0.05°C 0.04% + 0.10°C
100 Ω Pt (3916) -200 to 100 0.07°C 0.14°C
100 to 630 0.02% + 0.05°C 0.04% + 0.10°C
100 Ω Pt (3926) -200 to 100 0.08°C 0.16°C
100 to 630 0.02% + 0.06°C 0.04% + 0.12°C
10 Ω Cu (427) -100 to 260 0.2°C 0.4°C
120 Ω Ni (672) -80 to 260 0.1°C 0.2°C
Source current Source °C Allowable current2
  1 year 2 year  
1 mA 0.05°C 0.10°C 0.1 mA to 10 mA
0.0125% + 0.04°C 0.025% + 0.08°C
500 μA 0.06°C 0.12°C 0.1 mA to 1 mA
0.017% + 0.05°C 0.034% + 0.10°C
250 μA 0.06°C 0.12°C 0.1 mA to 1 mA
0.017% + 0.05°C 0.034% + 0.10°C
150 μA 0.06 C 0.12 C 0.1 mA to 1 mA
0.017% + 0.05°C 0.034% + 0.10°C
1 mA 0.05°C 0.10°C 0.1 mA to 10 mA
0.0125% + 0.04°C 0.025% + 0.08°C
1 mA 0.05°C 0.10°C 0.1 mA to 10 mA
0.0125% + 0.04°C 0.025% + 0.08°C
3 mA 0.2°C 0.4°C 0.1 mA to 10 mA
1 mA 0.04°C 0.08°C 0.1 mA to 10 mA
1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
Temperature, Thermocouples
      
Type Source °C Measure °C Source °C
    1 year 2 years 1 year 2 years
E -250 to -200 1.3 2 0.6 0.9
-200 to -100 0.5 0.8 0.3 0.4
-100 to 600 0.3 0.4 0.3 0.4
600 to 1000 0.4 0.6 0.2 0.3
N -200 to -100 1.0 1.5 0.6 0.9
-100 to 900 0.5 0.8 0.5 0.8
900 to 1300 0.6 0.9 0.3 0.4
J -210 to -100 0.6 0.9 0.3 0.4
-100 to 800 0.3 0.4 0.2 0.3
800 to 1200 0.5 0.8 0.3 0.3
K -200 to -100 0.7 1 0.4 0.6
-100 to 400 0.3 0.4 0.3 0.4
400 to 1200 0.5 0.8 0.3 0.4
1200 to 1372 0.7 1 0.3 0.4
T -250 to -200 1.7 2.5 0.9 1.4
-200 to 0 0.6 0.9 0.4 0.6
0 to 400 0.3 0.4 0.3 0.4
B 600 to 800 1.3 2 1 1.5
800 to 1000 1 1.5 0.8 1.2
1000 to 1820 0.9 1.3 0.8 1.2
R -20 to 0 2.3 2.8 1.2 1.8
0 to 100 1.5 2.2 1.1 1.7
100 to 1767 1 1.5 0.9 1.4
S -20 to 0 2.3 2.8 1.2 1.8
0 to 200 1.5 2.1 1.1 1.7
200 to 1400 0.9 1.4 0.9 1.4
1400 to 1767 1.1 1.7 1 1.5
C 0 to 800 0.6 0.9 0.6 0.9
800 to 1200 0.8 1.2 0.7 1
1200 to 1800 1.1 1.6 0.9 1.4
1800 to 2316 2 3 1.3 2
L -200 to -100 0.6 0.9 0.3 0.4
-100 to 800 0.3 0.4 0.2 0.3
800 to 900 0.5 0.8 0.2 0.3
U -200 to 0 0.6 0.9 0.4 0.6
0 to 600 0.3 0.4 0.3 0.4
BP 0 to 1000 1 1.5 0.4 0.6
1000 to 2000 1.6 2.4 0.6 0.9
2000 to 2500 2 3 0.8 1.2
XK -200 to 300 0.2 0.3 0.2 0.5
300 to 800 0.4 0.6 0.3 0.6

How to Rent from Transcat

Rent from Transcat - Step 1

1. Select Your Rental Product

  • Need help selecting a unit? Try using our Product Finder or search our available units
  • Can’t find what you are looking for? Is the rental unit you need, not available? Give us a call at 800-828-1470 or our chat feature to speak with one of our dedicated Rental Experts
Rent from Transcat - Step 2

2. Contact Our Team of Rental Experts

  • Contact us here or click below to submit your request for a rental quote and a member of our Rental Team will review the request and will reach out to you very soon
Rent from Transcat - Step 3

3. Select Your Rental Period & Complete Your Order

  • Our weekly period lasts 7 calendar days, while our monthly rental period lasts 28 calendar days
  • Provide your form of payment, sign the rental agreement and any other required documents, and we will ship you the unit