UNI-T UDP5080-40 Programmable DC Switching Power Supply, 1 Channel, 800W, 80V/40A

UNI-T UDP5080-40 Programmable DC Switching Power Supply, 1 Channel, 800W, 80V/40A

Order # UDP5080-40

Mfg # UDP5080-40

call-regular 800-828-1470
$2,086.37
Loading...
Loading...
  • Overview
  • Technical Resources

UNI-T UDP5080-40 Programmable DC Switching Power Supply, 1 Channel, 800W, 80V/40A

Order # UDP5080-40 | Mfg # UDP5080-40
$2,086.37
  • 800W / 0–80V / 0–40A — auto-ranging across the rated power envelope
  • Voltage accuracy ±(0.05% of set + 0.05% of rated); current accuracy ±(0.5% of set + 0.1% of rated)
  • Low ripple — 50mV p-p voltage, 80mA rms current (20 MHz BW)
  • CC/CV priority slope modes — choose voltage-first or current-first turn-on for DUT safety
arrow_drop_down

Tariff fees or manufacturer imposed surcharges may be applicable.

Overview

The UNI-T UDP5080-40 is a single-channel 800W programmable DC switching power supply delivering 0–80V and 0–40A with auto-ranging across the rated power envelope. It pairs a wide output range with the regulation accuracy, source-emulation and remote control expected of a professional programmable supply.

Voltage accuracy is ±(0.05% of set + 0.05% of rated) and current accuracy ±(0.5% of set + 0.1% of rated); ripple is held to 50mV p-p with a 100 ppm/°C temperature coefficient. A 2.4-inch TFT-LCD shows voltage, current and power together, and full SCPI control over USB and LAN drops the UDP5040-200 straight into LabVIEW, Python-VISA or any ATE framework.

  • 800W / 0–80V / 0–40A — auto-ranging across the rated power envelope
  • Voltage accuracy ±(0.05% of set + 0.05% of rated); current accuracy ±(0.5% of set + 0.1% of rated)
  • Low ripple — 50mV p-p voltage, 80mA rms current (20 MHz BW)
  • CC/CV priority slope modes — choose voltage-first or current-first turn-on for DUT safety
  • Adjustable internal resistance to 2.000Ω — emulate batteries, fuel cells and solar sources
  • List Mode — 128 programmable V/I/dwell steps, 1 to 9,999, infinite cycles, stand-alone
  • Front and rear output terminals (front limited to 10 A)
  • Multi-unit series/parallel — up to 4 parallel / 4 series
  • USB + LAN with full SCPI 1999.0 / IEEE-488.2; 2.4-inch TFT-LCD
  • Discharge-load control for rapid output bleed-down

Applications

  • Power-Electronics and Motor-Drive Development: 0–80 V spans 48 V / 60 V / 72 V battery and DC-bus rails common in motor-drive and industrial converter design. Adjustable slew rate controls how fast the bus is energised into capacitive DC links.
  • R&D Bench and Production: List Mode and SCPI scripting make repeatable bring-up and end-of-line routines straightforward without an attended operator.
  • Automated Test and Production: SCPI over USB or LAN plus stored List Mode sequences make the UDP5000 a clean fit for unattended characterisation, burn-in and end-of-line test.

Each Unit Includes

  • power cord (destination-country standard, 1.8 m)
  • four-conductor analog-interface flat cable (3.5 m)
  • USB cable (1.5 m)
  • M3 mounting screws
  • output-terminal protection cover
  • rack distribution bracket

Technical Resources