Cal Test Electronics CT4079-NA for Rent, Elditest Hi-Voltage Differntial Probe, 50MHz
Elditest Hi-Voltage Diff.Probe 50MHz

Order #: CT4079-NA-RENT2

Mfg #: CT4079-NA-RENT2

Questions about availability or need help? Contact Us:

(800) 633-0561
Call for price
Call for price

Cal Test Electronics CT4079-NA for Rent, Elditest Hi-Voltage Differntial Probe, 50MHz

Elditest Hi-Voltage Diff.Probe 50MHz

Order #: CT4079-NA-RENT2

Mfg #: CT4079-NA-RENT2

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price
Availability:
In stock
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

Differential probes allow for safe, accurate measurements between two voltage points where neither point is referenced to ground.

Model CT4079 features 200x/2000x attenuation settings, 50 MHz bandwidth and ±15 kV maximum differential - all in a compact, safety yellow housing. Compatible with oscilloscopes from all major manufacturers, the probe is ideal where high sensitivity and dynamic range is needed.

NA stands for the North American style power adapter (CT3957-NA).

  • Precise power semiconductor device measurements
  • Switching power supply design
  • Measurement of power converters
  • Precise measurement of motor drives
Features:
  • Meets IEC 61010-031 safety standard
  • Up to ±1.5 kV / ±15 kV differential
  • 50 MHz bandwidth (-3 dB)
  • Excellent CMRR
  • Power and over-range indicators
Transcat Rentals - Rent Equipment from the Industry Leader
   Try Before You Buy
   Save Time & Money
   Weekly and Monthly Rentals
   Access Our Large Inventory
   Long-term Discounts and Rent-to-Buy Options Available

Shop all Rentals

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Type Active Differential
Bandwidth 50 MHz
Rise Time 7 ns
Attenuation 200x/2000x
Accuracy ±2%
AC CMRR -80 dB @ 60 Hz
-60 dB @ 100 Hz
-50 dB @ 1 MHz
Input Impedance Between inputs: 40 MΩ // 1.3 pF
Each input to ground: 20 MΩ // 2.6 pF
Differential Voltage (DC+peak AC) ±1.5 V/±15 kV
Common-Mode Voltage (DC+peak AC) ±15 kV or 11 kVrms
Absolute Max. Voltage (DC+peak AC) ±15 kV or 11 kVrms
Swing ±8 V (±4 V into 50 Ω load)
Offset (Typ.) ≤5 mVDC
Noise (Typ.) <1 mVrms
Source Impedance (Typ.) 50 Ω
Power Supply External 9 VDC power supply
Power Consumption 200 mA about (9 VDC)
Operating Temperature/Humidity 0° to +50° C / 10% to 85% RH
Storage Temperature/Humidity -30° to +70° C / 10% to 90% RH
Cable Length 100 cm (separate lead)
Input Leads Length 60 cm (separate leads)
Weight 350 g
Dimensions 220 mm x 85 mm x 30 mm