NH Research 9410-36 for Rent, AC/DC Power Supply - 1 to 3 Phase 400V/Phase 90A/Phase, 36kW
AC/DC Power Supply,1-to 3-Phase 400V/Phase,90A/Phase,36kW

Order #: 9410-36-RENT2

Mfg #: 9410-36-RENT2

Questions about availability or need help? Contact Us:

(800) 633-0561
Call for price
Call for price

NH Research 9410-36 for Rent, AC/DC Power Supply - 1 to 3 Phase 400V/Phase 90A/Phase, 36kW

AC/DC Power Supply,1-to 3-Phase 400V/Phase,90A/Phase,36kW

Order #: 9410-36-RENT2

Mfg #: 9410-36-RENT2

Call for price

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Call for price
Availability: Call for Availability
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

The 9410 from NH Research is a four-quadrant (bi-directional) AC/DC source with selectable phase outputs, a built-in waveform-digitizing measurement system and robust line disturbance creation tools. When used in the regenerative (sink) mode, it sends returned power back to the facility mains rather than being dissipated as heat. The most frequent application of the 9410 is use as a grid simulator for testing PV inverters and other grid-tied products for compliance to industry standards.

Features

  • 8 models 4kW/10.5kVA to 96kW/252kVA
  • Output AC Voltage Ranges 175, 350VRMS L-N
  • Output DC Voltage 200, 400VDC
  • Output Frequency DC, 30 to 100Hz
  • Programmable 1, 2 or 3-Phase modes
  • Full 4 quadrant AC source operation
  • High resolution waveform capture on all V & I
  • Sink power regenerated back to facility
  • 9" Touch-Panel user interface
  • SCPI programming & NI LabVIEW drivers

Advantages

  • Bi-directional AC Inverter testing & µgrid simulation
  • More reactive power per kW
  • Simplifies automated test stand development
    • Software selectable 1, 2, or 3 Phase operation
    • Isolated digital inputs & outputs
    • Built-in SW watchdog & safety limits
  • Software tools to shorten test development time
    • PC-based tools & NI certified drivers
    • NI certified LabVIEW & IVI-C/IVI-COM drivers
    • Optional: Enerchron® test sequencer

Benefits

  • Regenerative, returns greater than 85% of power to the facility, which provides significant electrical savings.
  • Field upgradeable to higher power
  • Fully emulate any utility/grid condition
  • Simulate non-ideal Phase phase angles (A-B & A-C)
Transcat Rentals - Rent Equipment from the Industry Leader
   Try Before You Buy
   Save Time & Money
   Weekly and Monthly Rentals
   Access Our Large Inventory
   Long-term Discounts and Rent-to-Buy Options Available

Shop all Rentals

Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
1,2, or 3
Model Number 9410-36
AC Output Ratings
Phases/Output Channels
Power, Max (1Φ or 3Φ) 36kW/94.5kVA
Current Ranges (RMS per Φ) 18, 90 A/Φ
Current Ranges (RMS 1Φ) 54, 270A
Peak Current 3 X Max RMS
Frequency 30-100Hz (option up to 880Hz)
Voltage Ranges, L-N 175, 350V (Split Phase 250V Max)
Accuracy 0.2% Set + 0.2% Rng
Resolution 0.005% Rng
Distortion (THD) <1% @ 50/60Hz (Full power into resistive load at 480 VRMS (L-L))
Response Rate 1V/µS (10% to 90% measured at 90 degree turn-on into resistive load)
Custom Waveforms Sine, n-Step Sine, Triangle, Clipped-Sine, Arbitrary (user defined)
Phase Angle Control 0 to 359 degrees/1 degree resolution
DC Output Ratings
Power Max (1ch or 3ch) 36kW
Current Ranges (Per Ch.) 18, 90A/CH
Current Ranges (Per System) 54, 270A
Voltage Ranges 200, 400 VDC
Accuracy 0.2% Set + 0.2% Range
Ripple <800mV RMS
AC & DC Measurements
Peak Voltage 250, 500V
Accuracy (AC RMS) 0.1% Rdg + 0.06% Rng
Accuracy (DC) 0.1% Rdg + 0.1% Rng
Accuracy (Peak) 0.5% Rdg + 0.2% Rng
Resolution 0.005% Rng
Peak Current (per Ch.) 60, 300A
Accuracy (AC RMS) 0.2% Rdg + 0.06% Rng
Accuracy (DC) 0.2% Rdg + 0.06% Rng
Accuracy (Peak) 0.5% Rdg + 0.2% Rng
Resolution 0.005% Rng
Peak Power V Range x I Range
Accuracy (AC RMS) 0.2% Rdg + 0.06% Rng
Resolution 0.005% Rng
Additional Measurements Energy (Ah, kWh, kVAh), AC Crest Factor, AC Power Factor, Waveform Capture
Physical
Enclosure Cabinet
Size (HxWxD) 61 x 23 x 30"/1549 x 584 x 762mm
Weight 505lbs/229kg