RIGOL RP1002C
Current Probe,DC-1 MHz,100A peak

Order #: RP1002C

Mfg #: RP1002C

Questions about availability or need help? Contact Us:

(800) 633-0561
$2,507.40

RIGOL RP1002C

Current Probe,DC-1 MHz,100A peak

Order #: RP1002C

Mfg #: RP1002C

$2,507.40
The RP1002C current probe allows a general purpose oscilloscope to display AC and DC current signals up to 100 A Peak (70 A RMS) and it can also make AC and DC measurements with a multimeter by using the BNC-to-banana plug adapter.
Availability: Ships in 3-4 weeks

Product Highlights

  • Maximum Conductor Size: 11mm
  • Test Clamp
  • Test Clamp Button
  • BNC Interface
  • Power Supply Indicator
  • Overload Indicator
  • Zero Adjustment Knob
  • Range Switch
  • Range Switch
  • Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.

    Specifications

     

    Electrical Characteristics

     

    Current Range

    50mV/A, 500mV/A

    DC Accuracy, typical

    500mV/A: ±3% ±20mA

    (20mA to 14A peak range)

    50mV/A: ±4% ±200mA

    (200mA to 100A peak range)

    50mV/A: ±15% maximum

    (100A peak to 140A peak range)

    Gain versus frequency, typical

    See Appendix 1 Gain versus

    Frequency at 1 A Peak (Typical)

    Max. Working Current

    SeeVoltage and Current Ratings

    Max. Working Voltage

    SeeVoltage and Current Ratings

    Max. Floating Voltage

    SeeVoltage and Current Ratings

    Frequency Range

    DC to 1MHz (-3dB)

    Battery Type and Life, typical 

    9V NEDA 1604A, IEC 6LR61

    8 hours (1 each)

    DC Signal Linearity, typical

    See Appendix 3 DC Signal

    Linearity in 50mV/A Range (Typical)

    Phase versus frequency, typical

    See Appendix 4 Phase versus

    Frequency at 1 A Peak (Typical)

    Voltage and Current Ratings

     

    Parameter

    Max. Working Current (A)

    Max.

    Working

    Voltage

    (V)

    Max.

    Floating

    Voltage

    (V)

    50mV/A

    Range

    500mV/A

    Range

    DC

    70[1]

    7

    600

    600

    DC+AC

    Peak

    70[1]

    7

    600

    600

    AC Peak

    70

    7

    600

    600

    AC

    Peak-peak

    140

    14

    1200

    ----

    RMS     CAT

    III

    50

    5

    600

    600

    RMS CAT II

    50

    5

    600

    600

    RMS CAT I

    50

    5

    600

    600

     

    Physical Characteristics

     

    Dimensions

    262mm x 81mm x 36mm

    Max. Conductor under test Size

    10.3mm

    Dual-BNC Coaxial Cable Length

    100cm

    Weight

    310g (battery excluded)  

     

    Environmental Characteristics

     

    Working

    Temperature

    0℃ to +50℃

    Storage

    Temperature

    -20℃ to +80℃

    Humidity

    0℃ to +40℃, 95% humidity

    +40℃ to +50℃, 45% humidity

    Pollution Degree

     

    Certifications and Compliances

     

    EC Declaration of Conformity – Low Voltage 

    Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC

    Low Voltage Directive 73/23/EEC, as amended by 93/68/EEC

    EN 61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.

    EN 61010-2-032:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test.

    Additional Compliance

    IEC61010-1/A2:1995: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements.

    IEC61010-2-032:1994: Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-032: Particular requirements for hand-held current clamps for electrical measurement and test.

    Installation

    (Overvoltage)

    Category 

    CAT III: Equipment in a fixed industrial location (usually permanently connected)  CAT II: Equipment at this level includes appliances, portable tools, and similar products. Equipment is usually cord-connected. 

    CAT I: Secondary (signal level) or battery operated circuits of electronic equipment. 

    All products in this series