Fluke Calibration P3200 Hydraulic Deadweight Testers
Fluke Calibration P3200 Hydraulic Deadweight Testers

Order #: Fluke Calibration P3200 Hydraulic Deadweight Testers

Questions about availability or need help? Contact Us:

(800) 633-0561

Fluke Calibration P3200 Hydraulic Deadweight Testers

Fluke Calibration P3200 Hydraulic Deadweight Testers

Order #: Fluke Calibration P3200 Hydraulic Deadweight Testers

The P3200 Models are available in single or dual piston formats for increased operating ranges. Units can be supplied in psi, bar, kgf/cm², and MPa. These robust instruments are highly accurate, quick and easy to use. Units feature a built-in priming pump for large volume applications, piston flotation indicators and a high quality screw press for fine pressure control.

Why Buy the Fluke Calibration P3200 Series from Transcat? Calibration. Selection. Price.

Transcat is a leading supplier of Fluke Calibration instruments, and can offer accredited calibrations on new orders. Check out our ordering guide to ensure that we provide you with the very best product for your application. To request more information, technical support, get a quote, or place an order, feel free to call us, chat us, request a quote, or add to cart!

 

 

The P3200 Series is the culmination of over 50 years of experience in the production and design of high performance pressure standards. With features designed to improve accuracy and performance, increase reliability and simplify operation these deadweight testers can be used to calibrate virtually any pressure sensing device, including transducers, transmitters, gauges or pressure switches.

Each instrument is supplied with a detachable lid which makes it neat, compact and easily portable. The weight masses are stored in a high-quality case with a self locking mechanism to protect them during transit.

All units are provided with a traceable certificate of accuracy, weight mass details, 1/8 inch, 1/4 inch, 3/8 inch and 1/2 inch NPT or BSP female adaptors, operating fluid (where applicable) and spare seals.

The piston/cylinder assemblies are manufactured to the very highest standards with certified accuracies traceable to international standards laboratories such as the National Institute of Standards and Technology (NIST).

Pressure Ranges 
Distilled water operated Ranges to 10,000 psi (700 bar)
Accuracy
Accuracy ±0.015% of reading (±0.008% optional)
*Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.
Materials of Construction
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminum
Weight density 2.7 g/cm³
Piston material Tungsten carbide with nickel binder
Density- 15.0 g/cm³
Cylinder material Hardened martensitic steel
Tungsten carbide (water above 500 psi, 35 bar)
Thermal coefficiants of expansion Oil piston/cylinder 16.5 ppm/°C
Water (above 500 psi, 35 bar) 11 ppm/°C
General
Test port adapters 1/8, 1/4, 3/8 and 1/2 NPT or BSP
Instrument weight 36 lbs (16 kg)
Instrument size (W x D x H) 17.5 in x 12 in x 8.5 in (440 mm x 300 mm x 215 mm)
Mass set weight (typical) 80 lbs (36 kg)
Reservoir volume 150 cc
Screw press displacement 5.5 cc
Pump displacement 4.7 cc per stroke
O-ring seal materials Buna N as standard, Viton and EPDM available
Weight Increments
Minimum Standard Weight Increments Up to 500 psi (35 bar): 1 psi (0.1 bar)
500 to 5000 psi (35 to 350 bar): 10 psi (1 bar)
5000 to 20,000 psi (350 to 1400 bar): 20 psi (2 bar)
Model P3112: 1 psi (0.1 bar)
Optional Fractional Weights Up to 500 psi (35 bar): 0.1 psi (0.01 bar)
500 to 5000 psi (35 to 350 bar): 1 psi (0.1 bar)
5000 to 20,000 psi (350 to 1400 bar): 2 psi (0.2 bar)
Operating Fluids
Operating Fluids Distilled or deionized water
Options
PressCal Software Windows-based software program that allows users to easily apply all necessary corrections to enhance the deadweight tester performance. Calibration details are then stored and/or used to automatically create a calibration certificate. PressCal is provided as standard with all 0.008% instruments
Fluids Instruments can be supplied for use with Skydrol or brake fluids. Due to the aggressive nature of these fluids the standard nitrile seals and the acrylic reservoir tube will be replaced by either Viton or EPDM seals (as applicable) and an aluminum reservoir tube. For these or any other specialty fluid applications, please consult the factory.

Availability: Ships in 2-3 Weeks
Grouped product items
Product Name Qty
No options of this product are available.
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

  • Pressure ranges to 10,000 psi (700 bar)
  • 0.015% of reading accuracy standard (0.008% optional)
  • Single or dual piston formats
  • Built-in hand pumps standard
  • Mounted spirit level with adjustable feet
  • Units can be trimmed to local gravity FOC