The Endress+Hauser RN221N Active Barrier with Optional HART Diagnosis
Endress+Hauser RN221N Active Barrier with Optional HART Diagnosis

Order #: Endress+Hauser RN221N Active Barrier Optional HART Diagnosis

Questions about availability or need help? Contact Us:

(800) 633-0561

The Endress+Hauser RN221N Active Barrier with Optional HART Diagnosis

Endress+Hauser RN221N Active Barrier with Optional HART Diagnosis

Order #: Endress+Hauser RN221N Active Barrier Optional HART Diagnosis

The active barrier RN221N supplies e.g. a transmitter with power, if required also in the Ex-area, and then transmits the galvanically isolated signal. With the optionally available HART® monitoring the status of the transmitter is monitored. If an error arises a relay at the RN221N sends an alarm. The relay has to be actively set back. Thus even just briefly occurring errors can be easily located.

Availability: Ships in 2-3 Weeks
Grouped product items
Product Name Qty
No options of this product are available.

Product Highlights

  • Wide range power supply, flexible power source
  • Compact side by side DIN rail housing
  • International Ex approvals, Germanischer Lloyd / marine approval
  • Bidirectional HART® transmission. Communication sockets for HART® sensor setting up. Evaluation of status information from connected transmitter with HART® protocol.
  • Primary or secondary master operating mode, automatic selection
  • Sensor monitoring with early-warning system
  • Manual or automatic reset of the relay contact

Field of Application

  • Galvanic isolation of 4 to 20 mA current circuits
  • Removing large loop circuits
  • Powering 2 wire transmitters
  • Monitoring of SMART transmitters with early-warning system
  • Intrinsically safe sensor supply for Ex-area
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Acquisition / Evaluation
Measuring PrincipleResistance Temperature Detector
FunctionActive barrier with power supply for safe seperation of 4...20 mA current circuit
CertificationATEX II(1)GD(Ex ia)IIC
FM USA IS
FM USA NI
CSA IS
CSA NI
IECEx Ex ia
TIIS Ex ia
GOST Ex i
GL ship approval
SIL
Hygenic WHG
Input1 x analog 4...20 mA
Output1 x analog 4...20 mA
Relay output1 x no contact
Auxiliary power supply / Loop power supply 20...250 V DC/AC
Dimensions (wxhxd)22.5 x 110 x 112 mm
(0.89" x 4.33" x 4.41")
OperationHART
Thermometer
Measuring PrincipleResistance Temperature Detector
Characteristic / ApplicationActive barrier with power supply for safe seperation of 4...20 mA current circuit.
Ex - approvalsATEX Ex i
FM USA IS
FM USA NI
CSA IS
CSA NI
IECEx Ex ia
TIIS Ex ia
NEPSI Ex ia

CertificationGOST Ex i
Germanischer Lloyd / marine approval
SIL
Hygenic WHG